CLADEX MAX Compact Laminate Panel SIZES



CCM
sizes
REGURAL :
2800 x 1300 mm = 3.64 m²
2500 x 1220 mm = 3.05 m²
2465 x 1245 mm = 3.06 m²
2150 x 0900 mm = 2.38 m²
3050 x 1300 mm = 3.96 m²

JUMBO:
4200 x 1860 mm = 7.81 m²
4200 x 1620 mm = 6.80 m²
3200 x 1620 mm = 5.18 m²
3650 x 1860 mm = 6.79 m²
3650 x 1530 mm = 5.58 m²
3050 x 1530 mm = 4.47 m²

Surfaces:
Pattern, Mat, Glossy

Core :
brown, black, kraft paper


img
CCM+
img
REGURAL :
2800 x 1300 mm = 3.64 m²
2440 x 1220 mm = 3.05 m²
3050 x 1300 mm = 3.96 m²

JUMBO :
3200 x 1620 mm = 5.18 m²
3650 x 1860 mm = 6.79 m²
3650 x 1530 mm = 5.58 m²
3050 x 1530 mm = 4.47 m²





img NB1871



Thickness:
DF Compact Laminate Panels 0.8-25mm
CCM-
img
REGURAL:
2800 x 1300 mm = 3.64 m²
2500 x 1220 mm = 3.05 m²
2465 x 1245 mm = 3.06 m²
2150 x 0900 mm = 2.38 m²
3050 x 1300 mm = 3.96 m²
2440 x 1220 mm = 3.05 m²

JUMBO:
4200 x 1860 mm = 7.81 m²
4200 x 1620 mm = 6.80 m²
3200 x 1620 mm = 5.18 m²
3650 x 1860 mm = 6.79 m²
3650 x 1530 mm = 5.58 m²
3050 x 1530 mm = 4.47 m²
CLADEX MAX Compact Laminate Panels are double face ( DF) high pressure laminates ( HPL ) under quality EN438-6 that are produced in lamination presses with great pressure and and high temperature. Several volume of of kraft paper sheets impregnated with thermosetting resins bonded in high pressure process and colour sheet of decorative paper impregnated with melamine resins applied to both surfaces.
panel
CLADEX MAX Compact Laminate Panels is a high-quality construction product which is used especially for long terms facade claddings and more exterior applications (balconies ,fences,e.t.c).CLADEX MAX Compact Laminate Panels in accordance with EN 438-6 Type EDF with extremely effective weather protection & EGF with medium effective weather protection. CLADEX MAX Compact Laminate Panels, labeled with the CE-Mark necessary for their use in building applications.
sizes
Quality Specifications:
- Reaction to fire
- Specific weight
- Dimensional stability at elevated temperature
- Resistance to impact large diameter ball
- Resistance to climate change
- Flexural module
- Resistance to water vapour
- Strength to tensioning
- Resistance to UV light
- Resistance to atmospheric agents (moderate use )
- Resistance to humidity
- Resistance to atmospheric agents (severe use )
- Resistance to SO2
- Resistance to Salt
- Resistance to surface wear
- Resistance to Scratching
- Resistance to impresion in boiling water
- Resistance to staining
- Resistance to dry heat (180°)
- Resistance to cigarette burns
MACHINING & CUTTING
CLADEX MAX Compact Laminate Laminate with low sheen surfaces are subject to marring. Fabricating with peel coat on surface (if applicable) is recommended. Router base should be clean and free of burrs and debris. Table saws should be clean, flat, and free of burrs.

matching
STORAGE
CLADEX MAX Compact Laminate should be stored horizontally, with a caul board or other protective sheet placed on top to protect the material from possible damage. The material should be protected from moisture, and should never be stored in contact with the floor or an outside wall. Optimum conditions for storage are approximately 75°F (24°C), and 45% to 55% relative humidity.

storage
HANDLING
CLADEX MAX panels are classified as non hazardous for transportation purposes. Protective gloves should always be worn when handling due to sharp edges. It is recommended not to drag decorative surfaces on one another to avoid scratch the surface finish, equipment vacuum hosting may be used. Always transport the panels ensuring their stability. Transport must be done horizontally on flat, stable and whole pallets at least of equal size or bigger than the panels, taking care in securing compact laminates so as to prevent them from sliding, because of the possibility of sharp edges. Ensure that the two sides of the panels be kept clean and free of abrasive particles. Always try to have protective film of polyethylene. When removing panels from the stack always lift them up completely and don't drag them. During processing of the panels, always ensure that the surfaces are absolutely clean.

handligHPL
DRILLING:
CLADEX MAX Compact Laminate (grade 10, 12, and 20) can be sawed, drilled, routed, and fabricated using standard carbide tipped cutting tools. Holes for screws or bolts should be drilled oversized. Panel assemblies should be laminated with the appropriate backing sheet to minimize warpage. CLADEX MAX Compact Laminate are recommended for less criticalapplications. Optimum balancing is obtained by bonding the same surface laminate on both sides of the assembly with the same adhesive. Always align sanding marks in the same direction. All inside corners of cutouts must be radiused as large as possible, 1/8" (3.18mm) minimum, to avoid stress cracking. The edges and corners should be routed, sanded, or filed smooth and free of chips or nicks. Panels fabricated using metal substrates, which are more dimensionally stable than wood-based materials, should be installed in a framing system, which captures the perimeter of the panel yet allows for the normal dimensional movement of the laminate. This is to protect the panel edge and prevent edge lifting or separation from the substrate, which can occur under dry conditions.

driling
VISIBLE FIXING SYSTEM
MOST POPULAR & STRONGEST WAY OF INSTALLLATION FIXING: It's advisable to insert a flexible bush between the hole and the screw. The head of the screw shall be later covered by a plastic cap of the same colour of the panel. When fastening with through holes, advisable to adopt the rule of one fixed point which allows uniform longitudinal and transverse sliding of the edges of the sheet at all times. The fixed point hole will have a diameter a little bit bigger than that of the screw(enough for the insertion of the bush), while the other holes(sliding) will have a diameter at least 1.5 times bigger then that of the screw. Aluminum blind rivet with big head colour lacquered or with covering cap. Used for wall cladding on aluminum blind rivet with big head colour lacquered or with covered cap. Used for wall cladding on aluminum sub-constructions. The rivet, flexible mouthpiece and riveting tool must be suited to each other.

fixing system
INVISIBLE FIXING WITH SELF-TAPPING SCREWS:

In this case holes are not through holes and are made on the back of the panel. Pre-drilling is necessary and the hole diameter must be smaller than the external diameter of the screw, while the depth of the hole must be at least 1 mm longer than screw penetration. With this system it is possible to place hoooks if different type on the back of the panels according to the kind of hooking device present on the substructure: handling grooved etc. Hidden fastening of square cladding panels is possible with metal hanglers on the back side of the panel using undercut rivet anchor(Must be fastened with at least 4, no more than 6 individual hangers).

Thickness: 8,10,12mm
Thickness 8mm → 4mm
Thickness 10mm → 6mm


fixing system
fixing system
Joints

Due to the dimensional variations , the panels must be arranged so as to leave vertical and horizontal joints with a minimum width 6mm. Its recommended not to exceed a width of 10mm. The front of the frames should be covered by a protective strip or sealing strip of a width greater than the the of back bone.

     table         
FIXED POINT

Fixed point are used for uniform distribution(halving) of the expansion and shrinkage movements. The diameter of the drill hole in Cladex-Max is the same size as the diameter of the fastening.
NON FIXED

For reasons of stability and flatness, the edge spacing must be kept to without fail. The joints must be made at least 8mmwide so that changes in size can take place without hindrance.
         
    
GLUE SYSTEM

Gluing system is a clean and simple solution fro rear ventilated facedes visible roof underfaces , reveal and much more . Advantages of Glue system Excelllent appearance no fastening elements can be seen from the front side simple and fast installation tough movement / absorbing fastening see the follow video.
CLADEX MAX HPL PANELS / WEIGHTS PER SQUARE METERS:
CLAD-Ex 6mm | 8.26kgr/m2
CLAD-Ex 8mm | 11kgr/m2
CLAD-Ex 10mm | 13.8kgr/m2
CLAD-Ex 15mm | 21kgr/m2

CLEANING:
CLADEX MAX Compact Laminate Panels may be cleaned with a damp cloth and mild detergent. If in doubt about the suitability of a particular cleaner or detergent, check with CLADEX MAX . Use of abrasive cleaners, powders, scouring pads, steel wool, sandpaper, etc., can damage the finish of the decorative surface and are not recommended. Acid or alkaline-based cleaners, compounds, etc., will mar, etch, corrode, and permanently discolor the decorative surface of panel. Never use these materials on panel, nor allow bottles, rags, etc., contaminated with them to contact the surface. Accidental spills or splatters from these harsh materials should be wiped off immediately, and the area cleaned thoroughly with a damp cloth.
PACKING:
CLADEX MAX Compact Laminate Panels are packing in wooden or plastic pallets
CLAD-Ex CCM (2800 x 1300 x 6mm)/ 50 panels / pallet

packing


CLADEX MAX Compact Laminate Panels / Loading Container Info:
20ft container / CLAD-Ex CCM (6mm) 650 panels ( 2800 x 1300 mm)/ 2.366 m2
20ft img

CLADEX MAX Compact Laminate Panels / Loading Truck Info:
Full Truck / CLAD-Ex CCM (6mm) 700 panels ( 2800 x 1300 mm)/ 2.548 m2

packing